Maintenance
110
12.00 | SWS | Assembly and Operating Manual | en | 389456
Mount new sensor assembly
Ø Screw new sensor(5) into SWK(3) until sensor(5) touches the
detection shaft.
Ø Turn the sensor(5) half a turn out of its fitting.
Ø Look at the sensor assembly from above.
Ø Ensure that the detection shaft(7) and sensors(5) do not touch
each other, readjust the distance if necessary.
Ø Apply screw lock to screw(6) and fasten sensor(5) with
screw(6).
IMPORTANT!Risk of damage to the sensor! Carefully screw in
screw(6) until screw(6) touches the sensor, then tighten an
additional approx. 1/4 turn.
Check new sensor assembly
Ø Switch on power supply.
The sensor LED will illuminate.
Sensor signal is ON.
Ø Mount the SWK(3) to the adapter plate for sensor assembly(1)
with screws(4).
Observe the tightening torque for the mounting screws.
Ø Connect all compressed air lines.
Ø Lock and unlock the locking piston and check the signals of the
sensors.