Technical data
20
04.00 | WSG 50 | Assembly and operating manual | en | 389474
3.3 Nominal electrical data
NOTICE
Exceeding the specified nominal data can damage the product.
If in doubt, please discuss your application with SCHUNK.
Electrical operating data Value Note
Clamping voltage [V DC]
Min.
Typ.
Max.
22
24
28
Current drawn when idled [A] 0.1
Current drawn when holding [A] 0.85 Gripping force=80N
Positioning resolution [µm] 1.09
Controller integrated
Field bus interface Ethernet
PROFIBUS DPv0
PROFINET RT (optional)
CAN-Bus
RS-232
IO
Configuration interface web based
3.4 Interfaces and connections
The product has various interfaces for control. The
communications interface is selected and configured via the web-
based user interface, Configuration and diagnosis via the web
interface [
}
64].