Maintenance and cleaning
70
04.00 | WSG 50 | Assembly and operating manual | en | 389474
8 Maintenance and cleaning
The maintenance and lubrication intervals must be adapted to the
ambient and operating conditions. The following factors should be
taken into account here:
Extreme operating temperatures
The effects of condensation
High vibration loading
Use in a vacuum
Very dynamic operation
The effect of foreign substances (e.g. steam, acids, etc.)
Clean the product at regular intervals with a dry cloth to remove
all soiling and metal chips. These typically collect in the
depressions, on the linear guides for the base jaws and on the
edges of the housing.
NOTICE
Material damage due to insufficient lubrication!
In the case of long-term short travel, it is possible to dry the
product.
Every 1000 movements or at least once per day the product
should be moved through its full range of travel.