A01350693 Rev:P ECO: 7476 Date: 04/14/08 35
Reset (Escort) Codes
NOTE: The PM mode must be disabled to make any programming changes to the panel. (See
Section 10 of this manual)
NOTE: All Programming is stored in nonvolatile memory, which means that if the panel looses
power the programming will remain in memory
.
NOTE: To reset the panel to factory settings enter *309 *9876543214.
Each Exit Control Panel offers three separate four digit codes for escorting transmitters legally through a protected doorway or
hallway or resetting an alarm condition created by the presence of a transmitter while the exit door is open or hallway perimeter is
breached. These three codes are referred to as the Primary, Secondary, and Tertiary. The Primary and Tertiary codes allow for
resetting alarm conditions and escorting transmitters through protected areas when the Advanced Security Mode is not used (refer to
the section on Advanced Security Mode for more operation details of that feature). The Secondary code allows for resetting,
escorting, and programming in all conditions. This code allows transmitters to be escorted through a protected area while Advanced
Security Mode is active (refer to the section on Advanced Security Mode for more operation details of that feature).
Primary Code (any three digits proceeded by *). Factory Default *234
To change the
Primary code, follow the three listed steps without pausing for greater than one second between keystrokes.
1. Enter *567 or the currently programmed Secondary code
2. Enter *9876543210#
3. Enter new three digit code. One beep = Change accepted
Secondary Code (any three digits preceded by *) Factory Default - *567
To change the Secondary code, follow the three listed steps without pausing for greater than one second between keystrokes.
1. Enter *567 or the currently programmed Secondary code
2. Enter *9876543211#
3. Enter new three digit code. Two beeps = Change accepted
Secondary Code Reset
This will allow you to reset the secondary code to factory setting ( *567 ) .
1. Enter *309 *9876543212
Tertiary Code (any three digits proceeded by *). Factory Default - *751
To change the Tertiary code, follow the three listed steps without pausing for greater than one second between keystrokes.
1. Enter *567 or the currently programmed Secondary code
2. Enter *9876543212#
3. Enter new three digit code. Three Beeps = Change Accepted
Escort Time Factory Default 30 Seconds
Each Exit Panel has a time period for passing through a door without creating an alarm.
To change the Escort code, follow the three listed steps without pausing for greater than one second between keystrokes.
1. Enter *567 or the currently programmed secondary code
2. Enter *9876543215#
3. Enter new three digit time in seconds (up to a maximum of 900 seconds but not less then 15 seconds) followed by #
4. Two beeps = Change accepted; One beep = Change not accepted