A01350693 Rev:P ECO: 7476 Date: 04/14/08 39
To view the Exit Panel ID code, follow the three listed steps without pausing for greater than one second between keystrokes.
1. Enter*567 or the currently programmed Secondary code
2. Enter *9876543213#999
3. Three series of blinks (# of blinks for number in the code, i.e. one blink = 1) separated by pauses.
PM Mode Feature
The PM Mode feature allows the user to select a single event, (one lock time and one unlock time) to automatically lock and
unlock the door system for every day of the week. This will allow more control of unauthorized traffic through the
protected door during those times.
PM Mode Factory Default Disabled
To program the panel to arm and disarm at a selected time
1. Enter *567 *987654321 hold the one until one beep is heard
2. Enter current time of the day in military time
3. Enter unlock time in military time
4. Enter lock time in military time
To enable the PM mode feature:
1. Enter*567*987654321 hold the one until one beep is heard
2. Then enter 9999
3. Four confirmation beeps = change accepted
To disable the PM mode
1. Enter *567*987654321 hold the one until one beep is heard
2. Then enter 9009
3. One confirmation beep = change accepted
Software Version
To verify the software version:
1. Enter *567*2 and hold
2. Count the beeps. It should be a four digit number (10 beeps=0)
Elevator Mode
Elevator Mode Factory Default Disabled
In normal operation the AUX relay will operate normally, the NO relay will close during alarms and the NC relay will OPEN
during alarms. When the Exit Panel loses all power, the NC relay will remain Closed and the NO will remain OPEN. This feature
only affects the AUX relays when the power is powered down
To enable the elevator mode: Enter *567 *0 hold the 0 until 1 beep is heard
To disable the elevator mode: Enter *567 *0 hold the zero until 2 beeps are heard. When the elevator mode feature is enabled the
AUX relays will change to the alarm state when the panel loses power. (Relays will change state).