Multi-room mode
58
▷ Set the RF power level of the receiver to the recommended
RF power level according to the room size as indicated in
the Sennheiser Control Cockpit.
▷ Perform a walk test to ensure the best reception coverage.
▷ If necessary adjust the RF power level and repeat the walk-
test for verification.
▷ Connect a LAN cable supplying PoE to the Dante I / PoE /
Ctrl RJ-45 sockets of all other SL Multi-Channel Receiver
DW units of the room (see „Connecting the receiver“).
They will synchronize with the Master.
▷ Set all other multi-channel receivers to the same RF power
level as the Master receiver.
▷ Then, switch on all SL Rack Receiver DW units.
They will synchronize with the Master receiver.
▷ Power cycle (switch off and on again) the rack receivers.
The Master receiver must be switched on all the time.
▷ Switch off all devices in this room before setting up the de-
vices in the next room.