Chapter 3 Operating Instructions
C4000 Micro/Basic/Basic Plus/Eco
16 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 8009423/YT79/2016-03-14
Subject to change without notice
Product description
3.4.3 Scanning range
The safety light curtain is available with different scanning ranges. An overview is con-
tained in Tab. 6.
Only use devices with a scanning range that matches the protective field width!
If the scanning range is set too low, the light curtain may not switch to green.
If the scanning range is set too great, the light curtain may malfunction. This would
mean that the operator is at risk.
The additional front screens, which are available as accessories (see page 61), reduce
the effective scanning range per additional front screen by 8 %.
Physical
resolution
Available scanning
ranges
Scanning range with 1
additional front screen
Scanning range with 2
additional front screens
14 mm
0–2.5 m
1–5 m
0–2.3 m
0.9–4.6 m
0–2.1 m
0.7–4.2 m
30 mm 0–6 m 0–5.5 m 0–5 m
The deflector mirrors available as accessories (see page 62) reduce the overall scan-
ning range depending on the number of deflector mirrors in the light path (see section
11.7.1 for PNS75 and section 11.7.2 for PNS125).
Do not use deflector mirrors if the formation of droplets or heavy contamination of the
deflector mirrors is to be expected!
The formation of droplets of heavy contamination can be detrimental to the reflection
behaviour. The protective function of the system will be affected and the system will thus
become unsafe. This would mean that the operator is at risk.
Deflector mirror 14 mm 30 mm
1 × PNS75 4.4 m 5.0 m
2 × PNS75 2.4 m 3.3 m
1 × PNS125 4.4 m 5.3 m
2 × PNS125 2.8 m 3.8 m
The information in the table relates to 90° beam deflection per mirror and a protective
field height of 900 mm. If you need more advice on mirror applications, please get in touch
with your contact at SICK.
a
WARNING
Notes
Tab.
5
:
Scanning range of
the C4000 without and with
additional front screen
a
WARNING
Tab.
6
:
Scanning range when
using 1 or 2 deflector mirrors

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Micro and is the answer not in the manual?

SICK C4000 Micro Specifications

General IconGeneral
TypeSafety Light Curtain
Safety Integrity Level (SIL)SIL3
Performance Level (PL)PL e
Enclosure RatingIP65
Resolution14 mm
Supply Voltage24 V DC
SynchronizationOptical
ConnectionM12 connector
StandardsEN ISO 13849
Outputs2 safety outputs (OSSDs), 1 auxiliary output