Operating Instructions Chapter 5
C4000 Micro/Basic/Basic Plus/Eco
8009423/YT79/2016-03-14 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 31
Subject to change without notice
Electrical installation
5.1 System connection C4000 Basic (M26 × 6 + FE)
Pin Wire colour s Sender r Receiver
1 Brown 24 V DC input (voltage supply) 24 V DC input (voltage supply)
2 Blue 0 V DC (voltage supply) 0 V DC (voltage supply)
3 Grey
Test input:
0 V: External test active
24 V: External test inactive
OSSD1 (switching output 1)
4 Pink Reserved OSSD2 (switching output 2)
5 Red Reserved Start-up configuration 1
6 Yellow Reserved
External device monitoring
(EDM) or start-up configuration 2
FE Green Functional earthing Functional earthing
5.2 System connection C4000 Eco (M12 × 4 + FE)
Pin Wire colour s Sender r Receiver
1 Brown 24 V DC input (voltage supply) 24 V DC input (voltage supply)
2 White Reserved OSSD1 (switching output 1)
3 Blue 0 V DC (voltage supply) 0 V DC (voltage supply)
4 Black Reserved OSSD2 (switching output 2)
5 Grey Functional earthing Functional earthing
system connection
C4000 Basic (M26
×
6 + FE)
system connection
C4000 Basic (M26
×
6 + FE)
system connection
C4000 Eco (M12
×
4 + FE)
system connection
C4000 Eco (M12
×
4 + FE)