Operating Instructions Chapter 5
C4000 Micro/Basic/Basic Plus/Eco
8009423/YT79/2016-03-14 © SICK AG • Industrial Safety Systems • Germany • All rights reserved 29
Subject to change without notice
Electrical installation
5 Electrical installation
Switch the entire machine/system off line!
The machine/system could unintentionally start up while you are connecting the devices.
Ensure that the entire machine/system is disconnected during the electrical installa-
tion.
Ensure that downstream contactors are monitored!
Downstream contactors must be positively guided and monitored (see section 5.4 “Exter-
nal device monitoring (EDM)” on page 33)!
Connect OSSD1 and OSSD2 separately!
You are not allowed to connect OSSD1 and OSSD2 together, otherwise signal safety will
not be ensured.
Ensure that the machine controller processes the two signals separately.
a
WARNING

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK C4000 Micro and is the answer not in the manual?

SICK C4000 Micro Specifications

General IconGeneral
TypeSafety Light Curtain
Safety Integrity Level (SIL)SIL3
Performance Level (PL)PL e
Enclosure RatingIP65
Resolution14 mm
Supply Voltage24 V DC
SynchronizationOptical
ConnectionM12 connector
StandardsEN ISO 13849
Outputs2 safety outputs (OSSDs), 1 auxiliary output