NOTE
Min. and max. reading distances are measured radially from the device.
12.6.2 Overview of reading field diagrams
Scanning procedure: line scanner
CLV69x type Resolution Diagram Page
CLV690-0xxx Standard
Density
Reading field height/resolution over reading distance page 100
Min. and max. reading distance (DOF) for resolution 0.35 mm/aperture angle 40° page 101
Min. and max. reading distance (DOF) for resolution 0.35 mm/aperture angle 56° page 101
Min. and max. reading distance (DOF) for resolution 0.50 mm/aperture angle 40° page 103
Min. and max. reading distance (DOF) for resolution 0.50 mm/aperture angle 56° page 104
Scanning frequency characteristic curve page 105
CLV691-0xxx Low Density Reading field height/tilt over reading distance for resolution 0.50 mm page 111
Min. and max. reading distance (DOF) for resolution 0.50 mm/aperture angle 40° page 112
Min. and max. reading distance (DOF) for resolution 0.50 mm/aperture angle 60° page 113
Scanning frequency characteristic curve page 114
CLV692-0xxx High Density Reading field height/resolution over reading distance page 116
Min. and max. reading distance (DOF) for resolution 0.25 mm/aperture angle 40° page 117
Min. and max. reading distance (DOF) for resolution 0.35 mm/aperture angle 40° page 118
Min. and max. reading distance (DOF) for resolution 0.35 mm/aperture angle 56° page 119
Scanning frequency characteristic curve page 120
Scanning procedure: line scanner with oscillating mirror
CLV69x type Resolution Diagram Page
CLV690-1xxx Standard
Density
Reading field height/resolution over reading distance page 105
Min. and max. reading distance (DOF) for resolution 0.35 mm/aperture angle 40° page 106
Min. and max. reading distance (DOF) for resolution 0.35 mm/aperture angle 50° page 107
Min. and max. reading distance (DOF) for resolution 0.50 mm/aperture angle 40° page 108
Min. and max. reading distance (DOF) for resolution 0.50 mm/aperture angle 50° page 109
Scanning frequency characteristic curve page 110
Deflection width page 110
CLV691-1xxx Low Density Reading field height/tilt over reading distance for resolution 0.50 mm page 114
Min. and max. reading distance (DOF) for resolution 0.50 mm/aperture angle 40° page 112
Min. and max. reading distance (DOF) for resolution 0.50 mm/aperture angle 50° page 113
Scanning frequency characteristic curve page 115
Deflection width page 115
CLV692-1xxx High Density Reading field height/resolution over reading distance page 120
Min. and max. reading distance (DOF) for resolution 0.25 mm/aperture angle 40° page 121
Min. and max. reading distance (DOF) for resolution 0.35 mm/aperture angle 40° page 122
Min. and max. reading distance (DOF) for resolution 0.35 mm/aperture angle 50° page 123
Scanning frequency characteristic curve page 124
Deflection width page 124
TECHNICAL DATA 12
8014396/ZMG8/2017-07-04 | SICK O P E R A T I N G I N S T R U C T I O N S | CLV69x
99
Subject to change without notice