CAUTION
If an
y operating or adjusting devices other than those specified in this document are
used or other methods are employed, this can lead to dangerous exposure to radiation.
Only use the operating or adjusting devices specified in this document.
Only follow the methods specified in this document.
Do not open the housing, except for the purposes of the installation and mainte‐
nance work specified in these operating instructions.
2.2 Intended use
The deTec4 C4P-EAxxx3SC05 safety light curtain is an electro-sensitive protective
de
vice (ESPE) and is suitable for the following applications:
Access protection
The product may be used in safety functions.
The safety light curtain is only suitable as access protection if full coverage is guaran‐
t
eed in the event of an interruption of the protective field.
The deTec4 C4P-EAxxx3SC05 safety light curtain must only be used within the limits of
the prescribed and specified technical data and operating conditions at all times.
Any instance of improper use, incorrect modification, or manipulation of the deTec4
C4P-EAxxx3SC05 safety light curtain shall void any warranty provided by SICK AG;
furthermore, SICK AG shall not accept any responsibility or liability for any resulting
damage and consequential damage.
2.3 Inappropriate use
The safety light curtain works as an indirect protective measure and cannot provide
pr
otection from parts thrown out nor from emitted radiation. Transparent objects are
not detected.
Among others, the deTec4 C4P-EAxxx3SC05 safety light curtain is not suitable for the
following applications:
Outdoors
Underwater
In explosion-hazardous areas
At altitudes over 3,000m above sea level
In environments with increased levels of ionizing radiation
2.4 Requirements for the qualification of personnel
The safety light curtain must only be configured, installed, connected, commissioned
and ser
viced by qualified safety personnel.
Project planning
You need safety expertise to implement safety functions and select suitable products
for that purpose. You need expert knowledge of the applicable standards and regula‐
tions.
Mounting, electrical installation and commissioning
Y
ou need suitable expertise and experience. You must be able to assess if the machine
is operating safely.
2 S
AFETY INFORMATION
10
O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05 8028570/2023-07-27 | SICK
Subject to change without notice