8.3.3 Alignment with the FlexFix bracket or with the upgrade bracket
Prerequisites
•
A F
lexFix bracket or upgrade bracket is used to mount the sender and receiver.
Alignment with the FlexFix bracket or the upgrade bracket
T
he FlexFix bracket or upgrade bracket offer you the following adjustment options for
aligning the sender and receiver with each other:
•
Shift vertically
•
Rotate (±15°)
Figure 40: FlexFix bracket: adjust vertically/rotate
NOTE
R
ecommendation for aligning a long device so that it rotates uniformly in both brackets:
►
Grab the alignment device roughly in the center between the two brackets.
8.3.4 Indication of the alignment quality
Important information
NOTE
A
s soon as the diagnostic LEDs 1, 2 and 3 light up, the alignment is good and availabil‐
ity is stable.
Body parts or objects in the protective field (e.g., hand, tool, AR60 optional laser
alignment aid) may impair the indication of the alignment quality (at most diagnostic
LEDs 1 and 2 light up).
►
Ensure that no body parts or objects are in the protective field
Or
►
W
atch out for diagnostic LEDs 5, 6, 7 and 8. If diagnostic LEDs 5, 6, 7 and 8 light
up, the alignment is good and availability is stable.
COMMISSIONING 8
8028570/2023-07-27 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05
65
Subject to change without notice