13.4 Length of cable
Table 36: Maximum lengths of cable for wire cross-section 0.34mm
2
, c
opper wire
Single system
Separate connecting cables for
sender and r
eceiver
r
s
b c
S
r
s
b ≤ 50 m c ≤ 15 m
Connection of sender and receiver
v
ia T-connector on the sender
r
s
a
T
c
S
r
s
a ≤ 7 m c ≤ 10 m
Connection of sender and receiver
v
ia T-connector on the receiver
r
s
a
T
b
S
r
s
a, b ≤ 12 m
S Control cabinet with safety relay or safety controller
T T-connector
Table 37: Maximum lengths of cable for wire cross-section 0.25mm
2
, c
opper wire
Single system
Separate connecting cables for
sender and r
eceiver
r
s
b c
S
r
s
b ≤ 35 m c ≤ 12 m
Connection of sender and receiver
v
ia T-connector on the sender
r
s
a
T
c
S
r
s
a ≤ 5 m c ≤ 7 m
Connection of sender and receiver
v
ia T-connector on the receiver
r
s
a
T
b
S
r
s
a ≤ 8 m b ≤ 10 m
S Control cabinet with safety relay or safety controller
T T-connector