Prerequisites
T
he type codes of the sender and receiver must be identical at the following place
in the number sequence.
°
Variant 1: C4P-******0***
°
Variant 2: C4P-******1***
If the type codes at this place in the number sequence differ, the connection
between the sender and receiver must be disconnected.
Connecting the sender and receiver
C
onnect the following wires with each other in the control cabinet:
0V DC of sender and receiver
+24V DC of sender and receiver
MFP1 of sender and receiver
Alternatively, you can connect the sender and receiver to each other via a T-connector
(with an optional pushbutton for the laser alignment aid). In such cases, you only
require a cable to the control cabinet and the status will also be indicated on both
sides. Please note that the sender and receiver are protected jointly by one fuse when
a T-connector is used. In the T-connector, all contacts are routed from the female
connector to the same pins of both male connectors.
The T-connector must only be connected to the system connection of an individual
device.
Even if you do not use a T-connector, you can connect the sender and receiver with
identical cables. The advantage of this is that the sender and receiver can be switched
without changing the cables if the installation situation so requires, e.g., to prevent
mutual interference between systems in close proximity to each other.
Further topics
"A
ccessories", page 88
"Protection against interference from systems in close proximity to each other",
page 27
4.4.5 Laser alignment aid
Important information
DANGER
H
azard due to lack of effectiveness of the protective device
The integrated laser alignment aid switches the OSSDs to the OFF state.
Make sure that the outputs of the safety light curtain do not have any effect on the
machine when the integrated laser alignment aid is activated.
Only use the integrated laser alignment aid to align the safety light curtain.
Prerequisites
A pushbut
ton is connected.
A T-connector with pushbutton is connected.
A switch is connected.
Pushbutton
T
he pushbutton is mounted at the system connection of the sender between the
system plug and the connecting cable.
The pushbutton can be temporarily mounted for alignments or used to maintain a
permanent connection.