6.4 Extension connection (M12, 5-pin)
Pin assignment at the extension connection
21
4
3
5
Figure 35: Extension connection (female connector M12, 5-pin)
Table 14: SP1 system plug extension connection pin assignment (M12 female connector, 5-pin)
PIN Wire color
1)
s S
ender r Receiver
1 Brown 24V Out (voltage supply
out
put)
24V Out (voltage supply
output)
2 White Not assigned In1
(EDM input)
3 Blue 0V Out (voltage supply out‐
put)
0V Out (voltage supply out‐
put)
4 Black Sync-out In2
(R
eset pushbutton input:
RES)
5 Gray MFP2 MFP2
(
ADO [application diagnos‐
tic output] / IO-Link
1)