13 Technical data
13.1 Data sheet
Table 29: General system data
Minimum Typical Maximum
Protective field height, depending on
t
ype
300mm, 450mm, 750mm
Resolution (detection capability) 30mm
Protective field width
1)
2)
3)
Resolution 30mm 0m…24m 0…30m
Protection class
4)
III (IEC 61140)
Enclosure rating
5)
IP65 (IEC60529)
IP67 (IE
C 60529)
Supply voltage U
V
a
t the device
6)
7)
8)
19.2V 24V 28.8V
Current consumption of the overall
s
ystem (system connection via sys‐
tem plug)
2A
Residual ripple
9)
±10%
Synchronization Optical
Typ (IEC61496) Type 4
Category(ISO13849) Category 4
Performance level (ISO13849)
10)
PL e
Safety integrity level (IEC61508)
10)
SIL 3
Safety integrity level (IEC62061)
10)
SIL 3
PFH
D
(me
an probability of a danger‐
ous failure per hour)
1.53 x 10
-8
T
M
(mis
sion time) 20years (ISO 13849-1)
Safe status when a fault occurs At least one OSSD is in the OFF state.
Power-up delay of sender and
r
eceiver after supply voltage is
applied
2s
Test rod speed at which the test rod
is r
eliably detected
11)
0m/s … 1.6m/s
1)
If the protective fields are very wide, there is a possibility that all four diagnostic LEDs 1, 2, 3 and 4 will
no
t light up even when alignment is optimal.
2)
The minimum scanning range specifies a range in which a function is guaranteed to operate correctly
and safely under industrial conditions. A sufficient level of signal reserve to ensure very high availability is
included in the calculation.
3)
The typical scanning range specifies a range in which the safety light curtain operates correctly and safely
under industrial conditions. The level of signal reserve is enough to ensure high availability.
4)
SELV/PELV safety extra-low voltage.
5)
The specified enclosure rating only applies when the system plug is fitted.
6)
The external voltage supply must be capable of bridging a brief power failure of 20ms as specified in
IEC60204-1. Suitable power supply units are available as accessories from SICK.
7)
A fuse rated maximum 4A shall be installed in the 24VDC power supply circuit to the device in order to
limit the available current.
8)
All inputs of the safety light curtain must be supplied by the same voltage supply. If the sender and
receiver are connected to each other, they must be supplied by the same voltage supply.
9)
Within the limits of U
V
.
10)
For more detailed information on the exact configuration of your machine, please contact your relevant
SIC
K subsidiary.
11)
Direction of movement and axis of the test rod perpendicular to the protective field.
TECHNICAL DATA 13
8028570/2023-07-27 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05
81
Subject to change without notice