Minimum Typical Maximum
Cable diameter 5mm
Cable material of the system or
e
xtension connection
PUR
Extension connection Optional, female connector, M12, 5-pin
Length of cable for connecting
cables
"Length of cable", page 85
Lengths of cable for other cables on
t
he extension connection
10m
Ambient operating temperature
1)
2)
3)
-30°C +55°C
Air humidity (non-condensing) 15% 95%
Storage temperature -30°C +70°C
Housing cross-section 31mm × 34mm, plus bracket, see "Dimensional dr
aw‐
ings", page 86
Vibration resistance
4)
5…150Hz, 3,5mm/1g (EN 60068-2-6)
Shock resistance
5)
15g/6ms (EN 60068-2-27)
Class 3M4 (IEC TR 60721-4-3)
EMC According to IEC61496-1, IEC61000-6-2,
IE
C61000-6-4
1)
The temperature difference between sender and receiver must not exceed 25K.
2)
The cable belonging to the device incl. the associated connection plug must not be flexibly mounted
under –25°C
.
3)
Maximum ambient operating temperature over 1,000m above sea level: +50°C.
Maximum ambient operating temperature over 2,000m above sea level: +45°C.
4)
Test conditions per axis: 1octave/minute, 20 sweeps.
5)
Test conditions per axis: 200shocks.
13.2 Response time
Table 34: Response time for a single device
Protective field height in mm Response time in ms
Uncoded Code1 or code2
300 9 12
450 10 14
750 11 16
13.3 Power consumption
Table 35: Power consumption for sender and receiver
Protective field height in mm Typical power consumption for
sender in W
Typical power consumption for
r
eceiver in W
1)
Resolution 30mm Resolution 30mm
300 1.23 3.23
450 1.31 3.30
750 1.45 3.43
1)
Power discharged again via the OSSDs depending on the connected OSSD load must be added to the
t
able values.
13 T
ECHNICAL DATA
84
O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05 8028570/2023-07-27 | SICK
Subject to change without notice