Hold t
he NFC-capable mobile device near the marked NFC-area on the lower end
of the receiver to call up the diagnostic data.
Complementary information
T
he SICK Safety Assistant App is available for devices with the following operating
systems:
•
Android
•
iOS
3.2.11 System plug
Overview
T
he following system plugs are available for the safety light curtain:
•
SP1system plug
The system plugs are available in the following versions:
•
System plug with 5-pin system connection
•
System plug with 8-pin system connection
•
System plug with 5-pin system connection and 5-pin extension connection
•
System plug with 8-pin system connection and 5-pin extension connection
Functional scope
T
he following functions are available depending on the system plug used:
•
Beam coding
•
Restart interlock
•
External device monitoring (EDM)
•
Application diagnostic output
•
IO-Link
The SP1 system plug can be used on all of the senders and receivers of a single
system.
Using the system plugs
T
able 3: Use of SP1 system plug in a single system
SP1 system plug type code
1000 1200 1100 1300
Sender
✓
✓
1)
✓
✓
1)
Receiver
✓
•
Be
am coding
✓
•
Be
am coding
•
Restart inter‐
lock
•
External
device moni‐
toring
•
Application
diagnostic
output
✓
•
Be
am coding
•
Restart inter‐
lock
•
External
device moni‐
toring
•
Application
diagnostic
output
•
IO-Link
✓
•
Be
am coding
•
Restart inter‐
lock
•
External
device moni‐
toring
•
Application
diagnostic
output
•
IO-Link
✓
SP1 system plug suitable.
1)
At the sender, the 8-pin system connection is solely for the purposes of providing standardized wiring.
It is par
ticularly recommended if the 8-pin system connection at the receiver is used and the sender and
receiver are connected to each other via a T-connector.
3 P
RODUCT DESCRIPTION
16
O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05 8028570/2023-07-27 | SICK
Subject to change without notice