EasyManua.ls Logo

SICK deTec4 C4P-EA 3SC05 Series - Sender and Receiver Must Not be Installed such that They Are Rotated 180° Relative

SICK deTec4 C4P-EA 3SC05 Series
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 26: Sender and receiver must not be installed such that they are rotated 180° relative to
e
ach other
Prerequisites
Pr
oject planning is completed.
Assembly is carried out according to the project planning.
Dangerous condition of the machine is and remains switched off during mounting.
The outputs of the device do not affect the machine during mounting.
Only use SICK-approved brackets for mounting.
Take appropriate measures for vibration damping if vibration and shock specifica‐
tions exceed the values and test conditions specified in the data sheet.
Notes on mounting
Mount t
he sender and receiver on a level surface. (1)
1
Mount t
he sender and receiver such that a right-angled protective field is estab‐
lished, i.e., when mounted vertically at the same height. (2)
For minor adjustments when aligning, the sender and receiver can be adjusted
longitudinally in the brackets.
MOUNTING 5
8028570/2023-07-27 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05
43
Subject to change without notice

Table of Contents