Figure 26: Sender and receiver must not be installed such that they are rotated 180° relative to
e
ach other
Prerequisites
•
Pr
oject planning is completed.
•
Assembly is carried out according to the project planning.
•
Dangerous condition of the machine is and remains switched off during mounting.
•
The outputs of the device do not affect the machine during mounting.
•
Only use SICK-approved brackets for mounting.
•
Take appropriate measures for vibration damping if vibration and shock specifica‐
tions exceed the values and test conditions specified in the data sheet.
Notes on mounting
►
Mount t
he sender and receiver on a level surface. (1)
►
Mount t
he sender and receiver such that a right-angled protective field is estab‐
lished, i.e., when mounted vertically at the same height. (2)
►
For minor adjustments when aligning, the sender and receiver can be adjusted
longitudinally in the brackets.
MOUNTING 5
8028570/2023-07-27 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05
43