osition the brackets near the ends of the housing. For devices with a protective
field height >300mm, the distance between the bracket and the end of the
housing must not exceed 1/4 of the length of the housing. If the device is exposed
to strong vibrations during operation, mount the top bracket at a height where the
offset in the safety light curtain housing rests on the bracket. (3)
►
Ob
serve the tightening torque details for the particular bracket. Higher torques
may damage the bracket. Lower torques do not offer sufficient protection against
slipping of the sender and receiver. (4)
4
2,5 Nm -
3 Nm
5 Nm -
6 Nm
►
Mak
e sure that the sender and receiver are aligned correctly. The optical lens
systems of the sender and the receiver must be located opposite one another. (5)
5 MOUN
TING
44