Differing minimum distance to reflective surfaces for devices with a resolution of
30mm w
ith weld spark guard
If a device with a resolution of 30mm is used with the weld spark guard, the following
applies in contrast to other specifications in order to determine the minimum distance
from reflective surfaces:
1. Determine the distance D between sender and receiver in meters (m).
2. Read the minimum distance a in millimeters (mm) in the graph or calculate it
based on the respective formula (see table 44).
Figure 44: Diagram minimum distance to reflective surfaces for devices with a resolution of
30mm w
ith weld spark guard
Table 44: Formula for calculating the minimum distance to reflective surfaces for devices with a
resolution of 30mm with weld spark guard
Distance D between sender and
r
eceiver in m
Calculation of the minimum distance (a) from reflective
surfaces in mm
D ≤ 3m a = 262mm
D > 3m a = tan (5°) × 1000mm/m × D = 87,49 × 1mm/m × D
Table 45: Weld spark guard ordering information
Part Part number
Weld spark guard 2069268