Functionality of the pushbutton
•
Pr
ess the pushbutton once and release: integrated laser alignment aid is switched
on
•
Press the pushbutton again and release: integrated laser alignment aid is
switched off
Switch
The switch is not suitable for safety light curtains where the sender and receiver are
connected via a T-connector.
The switch is mounted in the control cabinet. A relay or a PLC can also be used as
a switch to enable the integrated laser alignment aid to be switched on and off via a
control panel, for example.
The switch must be connected in accordance with the circuit diagram below.
Figure 22: Switch for the integrated laser alignment aid
•
S1 c
losed: integrated laser alignment aid is switched on
•
S1 open: integrated laser alignment aid is switched off
IO-Link
If the sender and receiver are connected with each other, the laser alignment aid can
also be activated by a command from IO-Link.
Further topics
•
"C
onnection of sender and receiver", page 34
•
"IO-Link", page 36
•
"Accessories", page 88
4.4.6 IO-Link
Overview
T
he IO-Link connector is used to establish a connection between suitable devices and
an IO-Link master, enabling communication via IO-Link.
The following information can be output via IO-link:
•
Application diagnostic output status information
•
Device information and device status
•
Configuration of the device
•
Status of each individual light beam
•
Error history
•
Reasons for the last lockout
The following information can be controlled via IO-link:
•
LED signal behavior of the field indicator
•
Switching on and off of the integrated laser alignment aid
Complementary information
D
etailed information on how the IO-Link connector is connected can be found in the
assembly instructions for the IO-Link connector.