DANGER
Use of incor
rect test rods
Persons or parts of the body to be protected may not be detected in operation.
Only use the included test rod with the diameter specified on the type label of the
safety light curtain.
Do not use any test rods with a similar or the same diameter of other safety light
curtains.
DANGER
H
azard due to unexpected starting of the machine
Make sure that the dangerous state of the machine is and remains switched off
during the check.
Make sure that the outputs of the safety light curtain have no effect on the
machine during the check of the components.
DANGER
H
azard due to lack of effectiveness of the protective device
Persons and parts of the body to be protected may not be recognized in case of
non-observance.
Do not operate the machine if the field indicator lights up green or yellow during the
check!
If the field indicator lights up green or yellow during the check (even if only briefly)
work must stop at the machine.
In this case, the mounting and electrical installation of the safety light curtain
must be checked by qualified safety personnel.
NOTE
T
he integrated laser alignment aid switches the OSSDs to the OFF status.
Ensure that the integrated laser alignment aid is switched off during the check.
Prerequisites
T
he field indicator lights up green or flashes yellow.
The field indicator only flashes yellow if the internal restart interlock is configured
and a r
eset is required.
Approach
1. Move the test rod slowly through the area to be protected (e.g., machine opening),
as indicated by the arrow, see figure 23.
2. Watch the field indicator on the receiver during the check. The field indicator on
the receiver must continuously light up red. The field indicator must not light up
green or flash yellow.
4 P
ROJECT PLANNING
38
O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05 8028570/2023-07-27 | SICK