LEDs Meaning
OSSD Field Diagnostics LEDs
1 2 3 4 5 6 7 8
O
W
hite
Restart interlock is config‐
ur
ed.
Ö Y
el‐
low
The receiver has recog‐
ni
zed beams from several
senders.
Remedial measures:
Check the distance to
senders of the same
design.
Check the beam cod‐
ing of the receiver and
systems in close prox‐
imity.
Make sure that light
beams from a differ‐
ent sender cannot
hit the receiver (excep‐
tion: when one of
the two systems uses
code1 and the other
uses code2), see "Pro‐
tection against inter‐
ference from systems
in close proximity to
each other", page 27.
O R
ed Ö Ö
Y
ellow/
green
o o o o o o o o
Reset of the configuration
t
o factory settings is acti‐
vated.
O R
ed Ö
Green
The device is in configu‐
r
ation mode following a
change to the configura‐
tion.
O R
ed O
Green
The laser alignment aid of
t
he sender is switched on.
Its own protective field is
clear.
O R
ed O Red
Its own protective field is
int
errupted.
OR
The protective field is
clear.
The reset button has just
been actuated.
O R
ed Ö Yel‐
low
The protective field is
c
lear.
Reset required.
Ö Y
el‐
low
The reset pushbutton is
de
fective or is being actu‐
ated continuously. Check
the wiring of the reset
pushbutton.