EasyManua.ls Logo

SICK deTec4 C4P-EA 3SC05 Series - Page 75

SICK deTec4 C4P-EA 3SC05 Series
104 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table 26: LEDs on the receiver during normal operation
LEDs Meaning
OSSD Field Diagnostics LEDs
1 2 3 4 5 6 7 8
O
W
hite
EDM is configured.
O
White
Beam coding 1 or 2 is
conf
igured.
O
W
hite
Restart interlock is config‐
ur
ed.
Ö Y
el‐
low
The receiver has recog‐
ni
zed beams from several
senders.
Remedial measures:
Check the distance to
senders of the same
design.
Check the beam cod‐
ing of the receiver and
systems in close prox‐
imity.
Make sure that light
beams from a differ‐
ent sender cannot
hit the receiver (excep‐
tion: when one of
the two systems uses
code1 and the other
uses code2), see "Pro‐
tection against inter‐
ference from systems
in close proximity to
each other", page 27.
O R
ed Ö Ö
Y
ellow/
green
o o o o o o o o
Reset of the configuration
t
o factory settings is acti‐
vated.
O R
ed Ö
Green
The device is in configu‐
r
ation mode following a
change to the configura‐
tion.
O R
ed O
Green
The laser alignment aid of
t
he sender is switched on.
Its own protective field is
clear.
O R
ed O Red
Its own protective field is
int
errupted.
OR
The protective field is
clear.
The reset button has just
been actuated.
O R
ed Ö Yel‐
low
The protective field is
c
lear.
Reset required.
TROUBLESHOOTING 11
8028570/2023-07-27 | SICK O P E R A T I N G I N S T R U C T I O N S | deTec4 C4P-EAxxx3SC05
75
Subject to change without notice

Table of Contents

Related product manuals