Page #30 background imageLoading...
Page #30 background image
H
as the machine been retrofitted?
Have machine parts been removed?
Have modifications been made to the surroundings of the machine?
Have the protective device or its parts been dismantled?
Is it possible to enter the hazardous area without being detected?
Is the protective device damaged?
Is the protective device severely contaminated?
Is the front screen contaminated, scratched or destroyed?
Are there any damaged cables or open cable ends?
If one of the points applies, the machine should be shut down immediately. In this case,
the machine and the protective device must be checked by appropriately qualified
safety personnel.
4 P
ROJECT PLANNING
30
O P E R A T I N G I N S T R U C T I O N S | deTec4 Core 8014253/ZOH3/2017-08-04 | SICK
Subject to change without notice

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK deTec4 Core and is the answer not in the manual?

SICK deTec4 Core Specifications

General IconGeneral
Enclosure ratingIP65, IP67
Operating voltage24 V DC
Resolution14 mm
Supply voltage Uv24 V DC
Light sourceInfrared LED
Connection typeM12 connector