Chapter 13 Operating Instructions
DME5000
126 © SICK AG • Germany • Subject to change without notice 8009813/ZJV1/2017-05
Octet Active (1) Inactive (0)
Octet 17
Alarms
Bit 0 Device error
Bit 1 Internal device
temperature too high/too
low
Bit 2 Plausibility (see disp. PLB)
Bit 3 Bus communication
interference
Bit 4, 5, 6,
7
Not assigned
Octet 18 Supported alarms in Octet 17
Octet 19 Supported alarms in Octet 8
Octet 20
Warnings
Bit 0 Laser pre-failure message
Bit 1 ... 7 Not used
Octet 21
Warnings
Bit 1 Device inside temperature
Bit 2 Contamination
Bit 0, 3 ... 7 Not used
Octet 22 Supported warnings in Octet 20
Octet 23 Supported warnings in Octet 21
Octet 24 … 25 Profile version
Octet 26 … 27 Software version
Octet 28 … 31 Operating time (unit 0.1h)
Octet 32 … 35 Offset in units according to resolution
Octet 36 … 47 Not used
Octet 48 … 57 Serial number (2 spaces + 8 valid ASCII characters)
Octet 58 … 59 Reserved
Octet 60 Temperature (complement of 2)
Octet 61 Level measuring channel (complement of 2)
Octet 62 MF status
Octet 63 Bit 7 Laser on Laser off
Bit 0 ... 6 Not used