A lit LED indica
tes that the output or function is set.
b
Start configuration by pressing the Menu pushbutton.
Or:
b
Sw
itch to operating level 2 by pressing the Menu and Set pushbuttons simultane‐
ously for more than 1 s.
NOTE
If you do not press either of the pushbuttons for 15 seconds, the MLG-2 automatically
leaves the menu.
Table 20: Meaning of the displays
Symbol Meaning
L2 Control panel level 2 active
Q1…Q3 Switching output (device-specific)
QA1/QA2 Analog output (device-specific)
Level 1 (output settings)
For s
witching outputs
Object detection
Contamination warning
Height classification
Object recognition
Output inverted/20…4 mA
For analog outputs
NBB Number of beams blocked
FBB First beam blocked
LBB Last beam blocked
Level 2 (system settings)
Reset to the factory setting
Beam blanking for teach-in
Activate/deactivate alignment aid
Activate/deactivate cross-beam function
7 OPERATING THE MLG2 PRIME
38
O P E R A T I N G I N S T R U C T I O N S | MLG-2 Prime 8018715.16YM / 2020-02-13 | SICK
Subject to change without notice