Figure 27: Mounting the FlexFix bracket on a profile frame
Screwing the sender or receiver into the FlexFix brackets
Aft
er mounting the FlexFix brackets, screw the sender or receiver into the FlexFix brack‐
ets from the front. Then align the sender and receiver.
NOTE
The ML
G-2 can only be screwed in when both FlexFix brackets are in alignment. If nec‐
essary, use a water level to check the components are parallel.
Figure 28: Inserting the MLG-2 in the FlexFix brackets
b
Use an M5 scre
w to fix the position of the sender and receiver in the FlexFix
bracket.
MOUNTING 4
8018715.16YM / 2020-02-13 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 Prime
31
Subject to change without notice