Figure 30: Alignment with the FlexFix bracket
6.2 Alignment and teach-in
To ensure the alignment aid works perfectly, the device should be rotated once from the
lef
t bracket stop to the right stop. This makes the best possible settings for the input
sensitivity and ensures that the alignment aid shows the most helpful values.
Figure 31: Rotate the receiver once
6.2.1 MLG-2 Prime
The alignment aid is activated at the factory and the outputs are deactivated. A valid
me
a
surement is not possible. The MLG-2 deactivates the alignment aid automatically
after the teach-in process.
When the device is switched on, the four green LEDs on the right-hand side of the con‐
trol panel show the alignment quality.
COMMISSIONING 6
8018715.16YM / 2020-02-13 | SICK O P E R A T I N G I N S T R U C T I O N S | MLG-2 Prime
35