Figure 32: Alignment aid – LEDs alignment quality
1
LEDs for alignment quality
b
Align t
he MLG-2 such that as many LEDs illuminate as possible.
It may be that they do not all light up; this is normal. Even if not all of the LEDs
lig
ht up, the teach-in process adjusts each beam so that it is located in the opti‐
mum functional range.
b
No
w fix the position of the sender and receiver.
Teach-in
b
Pre
ss the Teach pushbutton (< 1 s).
2)
b
All LEDs light up briefly one after another (sequential light). The sensitivity is
stored.
Ö 1 Hz yellow
The yellow LED on the front flashes slowly.
If the teach-in process is successful, all LEDs on the control panel go out, as does the
yellow LED on the front of the device. The MLG-2 is operational.
If the teach-in process was unsuccessful, all LEDs on the control panel flash quickly, as
does the red LED on the front of the device.
b
Then, check that the MLG-2 is correctly aligned, that the front screens are clean
and that there are no objects located in the light path.
b
Then carry out the teach-in process again.
2)
On t
he ML
G-2 Prime, the teach-in process can also be triggered via IO-Link or the Teach input.