EasyManua.ls Logo

SICK MLG-2 Prime - Alignment Aid - Leds Alignment Quality

SICK MLG-2 Prime
62 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 32: Alignment aid – LEDs alignment quality
1
LEDs for alignment quality
b
Align t
he MLG-2 such that as many LEDs illuminate as possible.
It may be that they do not all light up; this is normal. Even if not all of the LEDs
lig
ht up, the teach-in process adjusts each beam so that it is located in the opti‐
mum functional range.
b
No
w fix the position of the sender and receiver.
Teach-in
b
Pre
ss the Teach pushbutton (< 1 s).
2)
b
All LEDs light up briefly one after another (sequential light). The sensitivity is
stored.
✓
Ö 1 Hz yellow
✓
The yellow LED on the front flashes slowly.
If the teach-in process is successful, all LEDs on the control panel go out, as does the
yellow LED on the front of the device. The MLG-2 is operational.
If the teach-in process was unsuccessful, all LEDs on the control panel flash quickly, as
does the red LED on the front of the device.
b
Then, check that the MLG-2 is correctly aligned, that the front screens are clean
and that there are no objects located in the light path.
b
Then carry out the teach-in process again.
2)
On t
he ML
G-2 Prime, the teach-in process can also be triggered via IO-Link or the Teach input.
6 COMMISSIONING
36
O P E R A T I N G I N S T R U C T I O N S | MLG-2 Prime 8018715.16YM / 2020-02-13 | SICK
Subject to change without notice

Table of Contents