Status information Meaning/effect
Warning field bit [WF LED]
L
ogical 1, if warning field 1 and warning field 2 of
the S3000 are clear or not used
Contamination [Weak]
L
ogical 1, if the front screen is contaminated
Reset required [Res. Req]
Logical 1, if reset required
Reset button pressed [Res. Pressed]
Logical 1, if the reset button is pressed on the
S3000
I/O error [I/O Error]
L
ogical 0, if there is no error on the S3000
Logical 1, if there is an error on the S3000
Control input A1 [In A1]
Logical 1, if the connection of control input A1 is
HIGH
1)
Control input A2 [In A2]
Logical 1, if the connection of control input A2 is
HIGH
1)
Control input B1 [In B1]
L
ogical 1, if the connection of control input B1 is
HIGH
1)
Control input B2 [In B2]
Logical 1, if the connection of control input B2 is
HIGH
1)
Control input C1 [In C1]
Logical 1, if the connection of control input C1 is
HIGH
1)
Control input C2 [In C2]
L
ogical 1, if the connection of control input C2 is
HIGH
1)
Control input D1 [In D1]
Logical 1, if the connection of control input D1 is
HIGH
1)
Control input D2 [In D2]
L
ogical 1, if the connection of control input D2 is
HIGH
1)
Allocated protective field clear [PF]
In dual field mode, in dual protective field mode
and in triple field mode: Logical 1, if the active allo‐
cated protective field is clear
Allocated warning field clear [WF]
or
Alloc
ated protective field 2 clear [PF2]
In dual f
ield mode: Logical 1, if the active allocated
warning field is clear
In dual protective field mode: Logical 1, if the active
allocated protective field 2 is clear
In triple field mode: Logical 1, if the active allo‐
cated warning field is clear
Simultaneous protective field clear
[S
im. SF]
In dual f
ield mode and in dual protective field
mode: Logical 1, if the simultaneously monitored
protective field is clear
In triple field mode: no function
Simultaneous warning field clear [Sim.
W
F]
or
Simultaneous protective field 2 clear
[Sim. SF2]
or
Allocated warning field 2 clear [WF2]
In dual f
ield mode: Logical 1, if the simultaneously
monitored warning field is clear
In dual protective field mode: Logical 1, if the
simultaneously monitored protective field 2 is clear
In triple field mode: Logical 1, if the active allo‐
cated warning field 2 is clear
Speed valid
2)
L
ogical 1, if a valid speed is present on the incre‐
mental encoder inputs
Logical 0, if an invalid speed is present on the
incremental encoder inputs
TECHNICAL DATA 12