7.4 Compatibility mode
Overview
T
o ensure compatibility, the S3000 safety laser scanners with firmware ≥ B02.41 can
be operated in compatibility mode.
Activate the compatibility mode in the device selection wizard in the CDS.
Figure 48: Compatibility mode
R
easons why you must activate the compatibility mode or the compatibility mode is
activated automatically by the CDS:
You are using one of the following devices in an EFI system:
°
S3000 Professional CMS
°
S3000 with firmware < B02.41 and serial number < 12210000
°
S3000 Standard, Advanced, Professional with an I/O module with serial num‐
ber < 12210000
°
S3000 Remote with an I/O module with serial number < 11240000
°
S300 Professional CMS
°
S300 Expert CMS
°
S300 with firmware < 02.10 and serial number < 12210000
°
S300 with system plug serial number < 12210000
You are configuring an S3000 with firmware < B02.41 and serial num‐
ber < 12210000.
You are configuring an S3000 Standard, Advanced, Professional with an I/O mod‐
ule with serial number < 12210000.
You are configuring an S3000 Remote with an I/O module with serial num‐
ber < 11240000.
You are using a safety laser scanner with a system plug in which a configuration is
saved that:
°
only supports the compatibility mode.
°
was configured in the compatibility mode.
°
was configured with a CDS version < 3.6.7.
You want to ensure newly configured devices can be replaced with old devices.
You want to replace old devices with new.
The table below shows the differences between the functions of the device variants in
the compatibility mode.
CONFIGURATION 7
8012029/ZA20/2019-11-14 | SICK O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store
65
Subject to change without notice