Table 8: Functions in the compatibility mode
Functions
Application diagnostic output, warning field output and
applic
ation diagnostic output for reset instead of universal
I/Os
C
Field sets comprising one protective field and one warning
field (dual field mode) or two protective fields (dual protec‐
tive field mode)
4
Programmable monitoring cases in stand-alone operation 4
Programmable monitoring cases in an EFI system 4
Speed routing using a Flexi Soft safety controller
NOTE
T
he user interface of the CDS in compatibility mode corresponds to the user inter‐
face of CDS version 3.6.6.
The related operating instructions delivered with the device are to be used for
older devices.
Interoperability in an EFI system depending on the firmware version
T
able 9: Required compatibility mode with different firmware versions of the S3000 in an EFI sys‐
tem with other S3000
Firmware
S3000 Standard
S3000 Standard
S3000 Advanced
S3000 Advanced
S3000 Professional
S3000 Professional
S3000 Professional CMS
S3000 Expert
S3000 Remote
S3000 Remote
Firmware
≥B02.41
B2.35
≥B02.41
B02.35
≥B02.41
B02.35
B02.35
1)
≥B02.41
B02.41
B02.35
S3000 Cold
Store
≥B02.41 X
C
X
C
X
C C
X X
C
1)
This variant supports exclusively the compatibility mode.
C = C
ompatibility mode required
X = Compatibility mode not required
2)
2)
Mak
e sure that you have the latest S3000 I/O module (S3000 Standard, Advanced, Professional with I/O module with serial number
> 12210000, S3000 Remote with I/O module with serial number > 11240000).
7 C
ONFIGURATION
66
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store 8012029/ZA20/2019-11-14 | SICK
Subject to change without notice