Approach
b
Ent
er a name for the application. The name can be a maximum of 16 characters
long.
7.5.2 Name of the scanner
b
Ent
er a device name for each of the safety laser scanners in the system. The name
can be a maximum of 8 characters long.
NOTE
•
Use me
aningful names, e.g., “front” and “rear” for vehicle monitoring. Unique
device names make the subsequent configuration steps easier.
•
On a host/guest system with two safety laser scanners, the device names must
always be different.
7.5.3 User data
You can enter your name in the N
ame of the user field. The name can be a maximum of
22 characters long. This is then added to the configuration protocol and in the diagnos‐
tics report.
7.5.4 Display direction of the 7-segment display
Overview
Y
ou can rotate the numbers shown on the 7-segment display by 180° using the CDS.
This is useful, for example, if the device needs to be rotated by 180° on account of the
mounting method.
Approach
b
Under 7-segment display, activate the Rotated by 180° option.
✓
After the draft configuration has been transferred to the device, the numbers of
the 7-segment display are rotated by 180°.
Complementary information
When the numbers shown on the 7-segment display are rotated, the dot on the 7-seg‐
ment display goes out.
7.6 Application
You can configure the safety laser scanner for the required application using the CDS.
D
epending on whether you select a stationary or a mobile application, different configu‐
ration options are available:
Table 11: Comparison of mobile and stationary applications
Mobile applications Stationary applications
Resolution
7 CONFIGURATION
68
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store 8012029/ZA20/2019-11-14 | SICK
Subject to change without notice