Figure 52: Creating a field set in the CDS
Protective fields and warning fields can cover an angle of up to 190° and have different
radial scanning ranges depending on the sensor head and the resolution configured.
WARNING
P
ersons or parts of the body to be protected may not be recognized or not recognized in
time in case of non-observance.
Before commissioning the machine or vehicle, check the configuration of the protective
fields, see "Commissioning", page 91, see "Checklist for initial commissioning and
commissioning", page 129.
b
Check the configured protective fields.
NOTE
If t
he protective field 3 or the warning fields 2 extend all the way to a wall or another
object (pillar, neighboring machine, shelf), there should be a distance of 100 mm
between the protective field or warning field and the object to prevent false triggering
1.
7 CONFIGURATION
80
O P E R A T I N G I N S T R U C T I O N S | S3000 Cold Store 8012029/ZA20/2019-11-14 | SICK