The S
ilent time defines the time, after sending the silent byte, for which the continuous
output of data can be interrupted to make it possible to access to the interface. The
factory default setting for the silent time is 5,000 ms.
Possible configurations for the Silent time:
•
The Silent time is automatically set to 5,000 ms.
•
The Silent time is customized to a shorter value between 60 and 4,980 ms.
The Send mode option is used to configure whether the measurement data output is to
be triggered as a Continuous data output or Data output only on request.
For further details on this topic, see the “Telegram Listing Standard” documentation
(part no. 9090807).