Parameter sets of signal modules
A.4 Parameters of analog input modules
S7-300 Automation System Module data
Manual, 08/2006, A5E00105505-04
A-9
Measuring method Code Measuring range Code
Resistance (4-wire
connection)
2#0100 150 Ω
300 Ω
600 Ω
10 k Ω
2#0010
2#0100
2#0110
2#1001
Resistance 4-wire
connection; 100 Ω
compensation
2#0110 52 Ω to 148 Ω
250 Ω
400 Ω
700 Ω
2#0001
2#0011
2#0101
2#0111
Thermal resistance +
linearization 4-wire
connection
2#1000 Pt 100 Klima
Ni 100 Klima
Pt 100 Standard range
Pt 200 Standard range
Pt 500 Standard range
Pt 1000 Standard range
Ni 1000 Standard range
Pt 200 Klima
Pt 500 Klima
Pt 1000 Klima
Ni 1000 Klima
Ni 100 Standard range
2#0000
2#0001
2#0010
2#0011
2#0100
2#0101
2#0110
2#0111
2#1000
2#1001
2#1001
2#1011
Thermocouples with
internal comparator
2#1010
Thermocouples with
external comparison
2#1011
Thermocouples +
linearization internal
comparison
2#1101
Thermocouples +
linearization external
comparison
2#1110
Type B [PtRh - PtRh]
Type N [NiCrSi-NiSi]
Type E [NiCr-CuNi]
Type R [PtRh -Pt]
Type S [PtRh -Pt]
Type J [Fe - CuNi IEC]
Type L [Fe-CuNi]
Type T [Cu - CuNi]
Type K [NiCr-Ni]
Type U [Cu -Cu Ni]
2#0000
2#0001
2#0010
2#0011
2#0100
2#0101
2#0110
2#0111
2#1000
2#1001
See also
Analog modules (Page 6-1)