EasyManua.ls Logo

Siemens F IWLAN - Communication and Approved Controllers; Software Requirements

Siemens F IWLAN
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview
1.7 Communication and approved controllers
Wireless Teach Pendant F IWLAN V2
22 Operating Instructions, 08/2010, A5E02453837-01
Additional access points and WLAN products are available in the Internet at: Industry Mall
(http://mall.automation.siemens.com
)
1.7 Communication and approved controllers
Number of communication connections
Communication link Wireless Teach Pendant F IWLAN V2
Quantity, max. 6
Approved PLCs
NOTICE
Safety-related communication
A non-fail-safe controller cannot ensure safety-related communication.
A SIMATIC S7F PLC is required for safety-related communication.
Approved protocols
The HMI device uses the following protocols for communication with the controller:
PROFINET
PROFIsafe Mode V2.0
1.8 Software requirements
You need the following software for fail-safe operation:
WinCC flexible 2008, SP2
STEP 7 V5.4, as of SP2
"SIMATIC S7 Distributed Safety V5.4" as of SP3 option package
Customer-specific WinCC flexible 2008 SP2 add-on for the Wireless Teach Pendant F
IWLAN
PRELIMINARY II
1.7.2010