Mounting and connection
4.5 Connecting the HMI device
Wireless Teach Pendant F IWLAN V2
Operating Instructions, 08/2010, A5E02453837-01
67
4.5.2 Opening and closing the terminal compartment
The connection compartment may not be opened while the HMI device is in operation.
Opening the connection compartment does not interrupt the power supply to the HMI device.
Note
Read the section "Safety instructions (Page 66)".
Requirement
● Screwdriver, size 6.5 x 150
Procedure – opening the connection compartment
Proceed as follows:
1. Lay the HMI device on its front side.
2. Loosen the screws.
&RYHUIODS
6FUHZ
3. Lift the cover.
The connection compartment opens.
Procedure – closing the connection compartment
Proceed as follows:
1. Close the cover of the connection compartment.
When closing the connection compartment, ensure that:
– The seal is present and properly positioned.
– The connection cables of the rechargeable buffer battery are not pinched.
2. Tighten the screws.
The connection compartment is open.