Planning the use
3.3 Insulation resistance, protection class and degree of protection
Wireless Teach Pendant F IWLAN V2
50 Operating Instructions, 08/2010, A5E02453837-01
Ambient climatic conditions for the docking station
The following table shows the permitted ambient climatic conditions for use of the docking
station.
Ambient condition Permitted range Comment
Operating temperature 0 to 40° C –
Humidity, relative 5 to 85%,
no condensation
Stress level 2,
according to IEC 61131-2
Humidity, absolute 1 to 25 g/m
3
–
Atmospheric pressure 1060 to 700 hPa Corresponds to an
elevation of –1000 to 2000 m
SO
2
< 0.5 vpm,
relative humidity < 60%,
no condensation
Test: 10 cm
3
/m
3
; 10 days
Pollutant concentration
H
2
S < 0.1 vpm,
relative humidity < 60%,
no condensation
Test: 1 cm
3
/m
3
; 10 days
Ambient climatic conditions for the RDIF tag
The following table shows the permitted ambient climatic conditions for use of the RFID tag.
Ambient condition Permitted range Comment
Operating temperature –25 to 80° C –
3.3 Insulation resistance, protection class and degree of protection
insulation resistance
Insulation resistance is demonstrated in the type test with the following test voltages in
accordance with IEC 61131-2:
Circuits with a nominal voltage of U
e
to
other circuits or ground
Test voltage
< 50 V 500 VDC
Protection class of the HMI device
HMI device Protection class according to IEC 60417-DB-HS
Front and rear panel Protection class III