AT command interface
Version 8 dated 15.03.00 134
Siemens Information and Communication Products
A
AT^SSET Set some unsolicited result codes
Test command
AT^SSET=?
Response
OK
Read command
AT^SSET?
Response
^SSET: <SIM ready>
Parameter
<SIM ready> 0 or 1 representing the setting of unsolicited result code presentation.
Set command
AT^SSET = [<SIM
ready>],[<bbnc>]
Response
Set the presentation of unsolicited result code.
Parameter
<SIM ready> Presentation of unsolicited result code ^SSIM READY:
0
Unsolicited result codes off
1 Unsolicited result codes on
<bbnc> BREAK is sent before NO CARRIER on dropped data call:
0
BREAK not sent
1 BREAK sent
Note:
The current value of the parameters can be stored using the command AT&W Store current parameter
to user defined profile
. On power up or with the ATZ command the value ist read from the EEPROM.
The factory default value (0) is set with command
AT&F Set all current parameters to manufacturer
defaults
.
Reference Unsolicited result code
Unsolicited result code sent after finish reading of SMS and phone books from SIM:
^SSIM READY