AT^MONP Monitor neighbour cells
Test command
AT^MONP[=<pe-
riod>]
Response
See execute command
Command is broken by any character sent to serial port
Parameter
<period>Display period in seconds
Execute command
AT^MONP
Response
chann rs dBm PLMN LAI NCC BCC C1 C2
46 49 -64 023102 0001 7 2 43 43
103 27 -83 023102 0001 7 3 21 21
39 22 -88 023102 0001 7 4 16 16
81 17 -93 023102 0001 7 5 11 11
104 16 -94 023102 0001 7 1 10 10
48 6 -104 023102 0001 7 7 0 0
54 3 -107 023102 0001 - - -1 -1
OK
Parameter:
chann Channel number
rs RSSI value (0–63)
dBm Receiving level in dBm
PLMN PLMN ID code
LAI Location area ID
NCC PLMN clour code
BCC BS clour code
C1 C1 coefficient for base station selection
C2 C2 coefficient for base station selection