AT command interface
Version 8 dated 15.03.00 41
Siemens Information and Communication Products
A
ATS4 Set response formatting character
Read command
ATS4?
Response
<n> OK
Set command
ATS4=<n>
Response
This parameter setting determines the character generated by the TA for result code and informati-
on text.
OK
Parameter
<n> 0-10-127 response formatting character
Note:
default 10 = LF
Reference
V.25ter
Note
ATS5 Set command line editing character
Read command
ATS5?
Response
<n> OK
Set command
ATS5=<n>
Response
This parameter setting determines the character recognized by TA as a request to delete the imme-
diately preceding character from the command line.
OK
Parameter
<n> 0-8-127 command line editing character
Note:
default 8 = backspace
Reference
V.25ter
Note
ATS7 Set number of seconds to wait for connection completion
Read command
ATS7?
Response
<n> OK
Set command
ATS7=<n>
Response
This parameter setting determines the amount of time to wait for connection completion when ans-
wering or originating a call.
OK
Parameter
<n> 0-60-255 number of seconds to wait for connection completion
Reference
V.25ter
Note
ATS8 Set number of seconds to wait when comma dial modifier
Read command
ATS8?
Response
<n> OK
Set command
ATS8=<n>
Response
No effect at GSM
OK
Parameter
<n> 0 no pause when comma encountered in dial string
2 Default value
1-255 number of seconds to wait
Reference
V.25ter
Note