3.14 Electronic brakes 
MICROMASTER 420 has 2 electronic brakes: 
DC braking     (refer to Section 3.14.1) 
Compound braking   (refer to Section 3.14.2) 
These brakes can actively brake the drive and avoid a possible DC link overvoltage 
condition. An inter-dependency as shown in Fig. 3-50 is present.  
DC braking
P1233 > 0
?
yes
no
DC braking
enabled
Compound
braking
P1236 > 0
?
Compound braking
enabled
disabled
no
yes
 
Fig. 3-50  Inter-dependency of the electronic brakes 
 
3.14.1 DC braking 
Parameter range:  P1230, P1232, P1233 
 r0053 Bit00 
Warnings - 
Faults - 
Function chart number:  - 
The drive decelerates along a parameterized braking ramp if an OFF1 / OFF3 
command is output. A "flat" ramp must be selected so that the drive inverter is not 
tripped (shutdown) due to the high regenerative energy which would cause a DC 
link overvoltage condition. The DC brake should be activated while the OFF1 / 
OFF3 command is present if the drive is to be braked faster. For DC braking, 
instead of continually reducing the output frequency / voltage during the OFF1 / 
OFF3 phase, a DC voltage / current is input (refer to sequence a). 
The drive can be brought to a standstill in the shortest time using DC current 
braking (DC brake). DC braking is selected as follows: 
 After OFF1 or OFF3 (the DC brake is released via P1233)  Sequence ➀ 
 Directly selected using BICO parameter P1230  Sequence ➁ 
For DC braking, a DC current is impressed in the stator winding which results in a 
significant braking torque for an induction motor. The magnitude, duration and 
frequency at which braking starts can be set for the braking current and therefore 