Issue 07/04 3 Functions
MICROMASTER 420 Operating Instructions
6SE6400-5AA00-0BP0
87
3.6 Inputs / outputs
3.6.1 Digital inputs (DIN)
Number: 3 + 1
Parameter range: r0722 – P0725
Function chart number: FP2000, FP2200
Features:
- cycle time: 2 ms
- switch-on threshold: 10.6 V
- switch-out threshold: 10.6 V
- electrical features: electrically isolated, short-circuit proof
External control signals are required for a drive converter to be able to operate
autonomously. These signals can be entered via a serial interface as well as also
via digital inputs (refer to Fig. 3-22). MICROMASTER has 3 digital inputs which can
be expanded to a total of 4 by using the 2 analog inputs. The digital inputs, as far
as their assignment, can be freely programmed to create a function. Whereby,
regarding the program, it is possible to directly assign the function via parameters
P0701 - P0704 or to freely program the function using BICO technology.
DIN channel (e.g. DIN1 - PNP (P0725 = 1))
24 V
T0
&
0
1
PNP/NPN DIN
0 ... 1
P0725 (1)
0 V
24 V
Debounce time: DIN
0 ... 3
P0724 (3)
CO/BO: Bin.inp.val
r0722
r0722
.0
Kl.8
P24 (PNP)
Kl.9
0 V (NPN)
Pxxxx BI: ...
P0701
Function
0
1
DIN channel (e.g. DIN1 - NPN (P0725 = 0))
24 V
T0
&
0
1
PNP/NPN DIN
0 ... 1
P0725 (1)
0 V
24 V
Debounce time: DIN
0 ... 3
P0724 (3)
CO/BO: Bin.inp.val
r0722
r0722
.0
Kl.8
P24 (PNP)
Kl.9
0 V (NPN)
Pxxxx BI: ...
P0701
Function
0
1
Fig. 3-22 Digital inputs