Technical data
7.4 Technical data, 400 V inverters
Power Module PM240-2
86 Hardware Installation Manual, 12/2015, A5E33294624B AD
7.4.3
Current derating depending on the pulse frequency, 400 V inverters
Article number
LO base load output current for a pulse frequency of …
[A]
2 Khz /
4 kHz
6 kHz
8 kHz
10 kHz
12 kHz
14 kHz
16 kHz
6SL3210-1PE11-8❒L1
1.7
1.4
1.2
1
0.9
0.8
0.7
6SL3210-1PE12-3❒L1
2.2
1,9
1.5
1.3
1.1
1
0.9
6SL3211-1PE13-2❒L1
3.1
2.6 2.2 1,9 1.6 1.4 1.2
6SL3210-1PE14-3❒L1
4.1
3.5
2.9
2.5
2.1
1.8
1.6
6SL3210-1PE16-1❒L1
5.9
5
4.1
3.5
3
2.7
2.4
6SL321❒-1PE18-0❒L1
7.7
6.5
5.4
4.6
3.9
3.5
3.1
6SL3210-1PE21-1❒L0
10.2
8.7
7.1
6.1
5.1
4.6
4.1
6SL3210-1PE21-4❒L0
13.2
11.2
9.2
7.9
6.6
5.9
5.3
6SL321❒-1PE21-8L0
18
15.3
12.6
10.8
9
8.1
7.2
6SL3210-1PE22-7❒L0
26
22.1
18.2
15.6
13
11.7
10.4
6SL321❒-1PE23-3❒L0
32
27.2
22.4
19.2
16
14.4
12.8
6SL3210-1PE23-8❒L0
38
32.3
26.6
22.8
19
17.1
15.2
6SL3210-1PE24-5❒L0
45
38.3
31.5
27
22.5
20.3
18
6SL3210-1PE26-0❒L0
60
51
42
36
30
27
24
6SL3210-1PE27-5❒L0
75
63.8
52.5
45
37.5
33.8
30
6SL3210-1PE28-8❒L0
90
76.5
63
54
45
40.5
36
6SL3210-1PE31-1❒L0
110
93.5
77
66
55
49.5
44
6SL3210-1PE31-5❒L0
145
123.25
108.75
---
---
---
---
6SL3210-1PE31-8❒L0
178
151.3
133.5
---
---
---
---
6SL3210-1PE32-1❒L0
205
---
---
---
---
---
---
6SL3210-1PE32-5❒L0
250
---
---
---
---
---
---
The permissible motor cable length depends on the particular cable type and the pulse frequency that