Installation and Startup
3-15
T
able 3-5
Download
T
able (continued)
Location Value Description of Function
Inject
Profile
V45
→
5000 Sets
module scan to 5 ms during inject
V46
→
32767
Sets max profile time to infinity
V47
→
32000
Sets inject transition pressure to maximum
V48
→
32000
Sets cavity transition pressure to maximum if
equipped
V49
→
0
Not used
V50
→
30 V
elocity scaling factor = 30 counts/ms
V51
→
50 V
elocity loop gain
V52
→
0V
elocity loop rate
V53
→
0V
elocity loop reset)
V54
→
0V
elocity/pressure operation = default
V55
→
50
Pressure loop gain
V56
→
0
Pressure loop rate
V57
→
0
Pressure loop reset
V58
→
0V
elocity/pressure data acquisition = default
V59
→
16000
Any number approximately half of shot size
V60
→
3000
Any number slightly greater than end of fill
position
V61–V68
→
0
Other steps to be filled in later
V69
→
8000 V
elocity = 1/4 speed
V70
→
4000 V
elocity = 1/8 speed
V71–V78
→
0
Other steps to be filled in later
V79
→
8000
Pressure = 1/4 of maximum
V80
→
8000
Pressure = 1/4 of maximum
V81–V88
→
0
Other steps to be filled in later
Note: The two steps shown for each profile can be from Step 1 to 10.