Installation and Startup
3-16
Startup
V
alues and Examples (continued)
T
able 3-5
Download
T
able (continued)
Location Value Description of Function
Pack
and Hold Profile
V89
→
5000 Sets
module scan to 5 ms during pack and hold
V90
→
0
Sets minimum profile position to end of stroke
V91
→
32000
Sets hold transition pressure to maximum
V92
→
32000
Sets cavity transition pressure to maximum if
equipped
V93
→
0
Not used
V94
→
30 V
elocity scaling factor = 30 counts/ms
V95
→
50 V
elocity loop gain
V96
→
0V
elocity loop rate
V97
→
0V
elocity loop reset
V98
→
0V
elocity/pressure operation = default
V99
→
50
Pressure loop gain
V100
→
0
Pressure loop rate
V101
→
0
Pressure loop reset
V102
→
0V
elocity/pressure data acquisition = default
V103
→
200 T
ime for first pack and hold step = 2 seconds
V104
→
500 T
ime for second pack and hold step = 3 seconds
Note accumulation
V105–V112 →
0
Other steps to be filled in later
V113
→
100
Set small velocity to open flow valve
V114
→
100
Set small velocity to open flow valve
V115–V122 →
0 Other
steps to be filled in later
V123
→
8000
Pressure = 1/4 of maximum
V124
→
2000
Pressure = 1/8 of maximum
V125–V132 →
0
Other steps to be filled in later
Note: The two steps shown for each profile can be from Step 1 to 10.