Installation and Startup
3-16
Startup
V
alues and Examples (continued)
T
able 3-5
Download
T
able (continued)
Location Value Description of Function
Pack
and Hold Profile
V89
5000 Sets
module scan to 5 ms during pack and hold
V90
0
Sets minimum profile position to end of stroke
V91
32000
Sets hold transition pressure to maximum
V92
32000
Sets cavity transition pressure to maximum if
equipped
V93
0
Not used
V94
30 V
elocity scaling factor = 30 counts/ms
V95
50 V
elocity loop gain
V96
0V
elocity loop rate
V97
0V
elocity loop reset
V98
0V
elocity/pressure operation = default
V99
50
Pressure loop gain
V100
0
Pressure loop rate
V101
0
Pressure loop reset
V102
0V
elocity/pressure data acquisition = default
V103
200 T
ime for first pack and hold step = 2 seconds
V104
500 T
ime for second pack and hold step = 3 seconds
Note accumulation
V105–V112
0
Other steps to be filled in later
V113
100
Set small velocity to open flow valve
V114
100
Set small velocity to open flow valve
V115V122
0 Other
steps to be filled in later
V123
8000
Pressure = 1/4 of maximum
V124
2000
Pressure = 1/8 of maximum
V125–V132
0
Other steps to be filled in later
Note: The two steps shown for each profile can be from Step 1 to 10.