Installation and Startup
3-17
T
able 3-5
Download
T
able (continued)
Location Value Description of Function
Plasticate
Profile
V133
5000 Sets
module scan to 5 ms during plasticate
V134
32767
Sets max profile time to infinity
V135
32767
Sets cure timer to infinity if so equipped
V136
0
Not used
V137
0
Not used
V138
30 V
elocity scaling factor = 30 counts/ms
V139
50 V
elocity loop gain
V140
0V
elocity loop rate
V141
0V
elocity loop reset
V142
0V
elocity/pressure operation = default
V143
50
Pressure loop gain
V144
0
Pressure loop rate
V145
0
Pressure loop reset
V146
0V
elocity/pressure data acquisition = default
V147
16000
Any number approximately half of shot size
V148
25000
Any number to accomplish shot size
V149–V156
0
Other steps to be filled in later
V157
500
Set small velocity to open flow valve
V158
500
Set small velocity to open flow valve
V157–166
0
Other steps to be filled in later
V167
500
Back pressure = near 0psi
V168
900
Back pressure = near 0psi
V169–V176
0
Other steps to be filled in later
Note: The two steps shown for each profile can be from Step 1 to 10.